pasobava.blogg.se

Set management ip brocade san switch
Set management ip brocade san switch











set management ip brocade san switch
  1. #Set management ip brocade san switch password#
  2. #Set management ip brocade san switch zip#
  3. #Set management ip brocade san switch windows#

Send the output of switch> supportsave from all the switches involved in the issue.

#Set management ip brocade san switch zip#

After collecting the logs, the user can zip the directory and upload to NetApp.

#Set management ip brocade san switch password#

  • Next, perform the same steps as above, this time using the username and password of the UNIX host, specifying SCP for the protocol, and specifying the name of the directory created to collect the logs.
  • The easiest method is by using SCP. Verify that SCP is installed on the host, and a directory has been created on the root volume of the host.
  • #Set management ip brocade san switch windows#

  • If a Windows host is not available to FTP, a UNIX host can be used as well.
  • Saving support information for switch:brocade200e-rtp, module:FABRIC. Saving support information for switch:brocade200e-rtp, module:TRACE_NEW. Saving support information for switch:brocade200e-rtp, module:TRACE_OLD. Saving support information for switch:brocade200e-rtp, module:RAS.
  • Press Enter the output files will be sent to the destination:.
  • Enter the name of the directory you created on the FTP root for case number and the specific switch:.
  • Specify the transfer protocol, in this case ftp or sftp:.
  • Password:, or just press enter for “blank” User Name:, or just press enter for “blank”
  • Enter the credentials for SFTP, or leave it blank for an anonymous FTP:.
  • Enter the IP address or host name of the FTP server:.
  • At the command prompt, type y to proceed:.
  • Set an action for where alerts are generated, such as RASLog, email, or SNMP. There will be two trace dump files transferred after running this command. related alerts from the FC SAN fabric management tools, first determine if your issues are one of the following more typical causes. Note: The supportsave transfers the existing trace dump file first, then automatically generates and transfers the latest one. If your DHCP server is not on the same subnet as the switch, use a static IP address. The DHCP client can only connect to a DHCP server that is on the same subnet as the switch. Any ISL of a switch that goes away from principle switch is a downstream. Any ISL of a switch that takes to the Principal switch is a upstream. Principal switch ensures that each switch in a SAN have different domain ID. Principal switches maintain unique domain ID across the fabric. This command collects RASLOG, TRACE, supportShow, core file, FFDC data, and other support information from both active and standby CPs, and then transfer them to the FTP/SCP/SFTP server or a USB device. When using DHCP, the switch obtains its IP address, subnet mask, and default gateway address from the DHCP server. What is the Principal switch in a Brocade SAN.
  • Once a FTP server with the named folder has been created, log into the Brocade switch and run the supportsave command:.












  • Set management ip brocade san switch